Released by FDA: 6/19/00. Posted by FDA: 6/29/00 Sun Piao-Yang Dear Mr. Sun: This is regarding an inspection of your active pharmaceutical ingredient (API) manufacturing facility in Lianyungang, China, by the United States Food and Drug Administration on March 6-7, 2000. The inspection revealed significant deviations from U.S. good manufacturing practices in the manufacture of APIs, and resulted in the issuance of an FDA Form 483 to you at the completion of the inspection. These deviations cause these APIs to be adulterated within the meaning of Section 501(a)(2)(B) of the Federal Food, Drug, and Cosmetic Act. Section 501(a)(2)(B) of the Act requires that all drugs be manufactured, processed, packed, and held according to current good manufacturing practice. No distinction is made between active pharmaceutical ingredients and finished pharmaceuticals, and failure of either to comply with CGMP constitutes a failure to comply with the requirements of the Act. We have reviewed the April 18, 2000, written response to the FDA-483 observations submitted to FDA by [confidential, deleted by FDA]. We have concluded that this response lacks sufficient details, explanations, or documentation to adequately address all of the significant deviations observed during the inspection. Our concerns regarding the most significant observations are discussed below: 1. Master production records were not approved by appropriate personnel and failed to include complete manufacturing and control procedures. 2. Batch production records did not adequately document the steps taken or the individuals performing and checking each step in the production of each batch.
3. Manufacturing facilities were not maintained in a good state of repair.
4. Equipment cleaning records are incomplete and equipment cleaning procedures have not been validated. The previous inspection in November 1994 also reported a similar deficiency regarding validation of the [confidential, deleted by FDA] cleaning procedure.
5. Laboratory equipment, methods, and procedures were deficient. [confidential, deleted by FDA] and [confidential, deleted by FDA] equipment were not calibrated, there was no SOP for calibrating the [confidential, deleted by FDA] apparatus, analytical methods were different than what is described in the subject DMFs, system suitability tests were not performed, degradation studies were not performed, the analytical method for residual solvents was not validated, and there were no written procedures for cleaning reused pipets. 6. Laboratory records were incomplete. Laboratory raw data was not properly recorded or reviewed, changes in raw data were not initialed or dated, in-house analytical methods were not properly reviewed or approved, and the humidity in stability chambers was not recorded.
The above deficiencies are not to be considered as an all-inclusive list of the deficiencies at your facility. FDA inspections are audits which are not intended to determine all deviations that exist at a firm. If you wish to continue manufacturing APIs for use in the U.S.. it is the responsibility of your firm to assure compliance with U.S. standards of good manufacturing practice for active pharmaceutical ingredients. We recommend that you evaluate your facility and quality control systems for CGMP compliance on an overall basis. Until the FDA reinspects your facility and confirms that these deficiencies have been corrected and the facility is compliance with CGMP, this office will recommend disapproval of any applications listing your firm as a manufacturer of APIs. If corrections are not initiated promptly, any API manufactured by your firm may be denied entry into the United States. Please direct your written response to the issues discussed in this letter to Compliance Officer John M. Dietrick at the address shown above. To schedule a reinspection of your facility after corrections have been completed, send your request to: Director, International Drug Section, HFC-133, Division of Emergency and Investigational Operations, 5600 Fishers Lane, Rockville, Maryland, 20857. You can also contact that office at (301) 827-5655 or by FAX at (301) 443-6919.
|
|
|